MC200

Digital Multicare Controller

MC200

The MC200 has been specifically designed for use with the Apollo Lighting Multicare luminaire equipped with DALI control gear, in order to meet the three lighting level requirements necessary for overbed illumination.

  1. 'Patient Reading' appropriate for day to day use
  2. 'Inspection' lighting
  3. 'Examination' lighting

Suitable for flush or surface mounting installation as required.

Operation

  • To achieve patient reading lighting as described above, turn on the left switch
  • To achieve inspection lighting, turn on right switch
  • To achieve examination lighting, turn on both switches and fade the fitting to full output using the left switch

Order Code

  • MC200

Dimensions

MC200 Dimensions
W H
90 90

Technical

Push To Make Switch Contacts10A nominal rating, single gang, single pole, normally open
Push To Make Switch4.0mm² conductors
Mains Switch Contacts20A nominal rating, single gang, single pole, two way
Mains Switch Terminals4.0mm² conductors
MountingSuitable for installation on 72 x 72 x 41mm deep single gang back box (not supplied)

Wiring

MC200 Wiring Diagram